TM 10-4320-324-14
Table 5-1. Troubleshooting- CONT.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
FRAME ASSEMBLY
1.
UNIT DOES NOT TRACK STRAIGHT.
Step 1. Inspect for damaged towbar.
Replace towbar.
Step 2. Inspect for bent, broken, or damaged frame.
Refer to paragraph 5-28 and repair as required.
Refer to paragraph 5-28 and replace frame assembly.
Step 3. Inspect for bent, broken, or damaged axle.
Notify general support maintenance.
Section III. MAINTENANCE PROCEDURES
5-6
Noise Enclosure Panels Repair.
This task covers:
Repair
INITIAL SETUP:
Tools
Tool kit, general mechanics, item 35, section III,
Equipment Condition
appendix B
Remove only panels and components in the
affected area which require repair.
References
TM 9-237
The noise enclosure panels consist of the following items: air discharge compartment, cooling air compartment, roof
panel, access doors, control box panels, front panels, upper side panels, lower rear panel, bottom panel, lower side
panels, and exhaust enclosure. Repair of the noise enclosure panels consists of welding defective components. Refer to
TM 9-237, Operator's Manual for Welding Theory and Application for Procedures.
5-6
|