TM 10-4320-324-14
(2)
Disassemble control panel instruments as follows:
(a) Remove three nuts (1), three lockwashers (2), three screws (3), and discharge gauge (4).
(b) Remove three nuts (5), three lockwashers (6), three screws (7), and suction gauge (8).
(c)
Remove four elbows (9 and 10) and two straight adapters (11).
(d)
Remove 12 nuts (12), 12 lockwashers (13), four loop clamps (14), 12 screws (15), and four panel
light brackets (16).
(e) Remove nut (17), lockwasher (18), screw (19), and loop clamp (20) from each light bracket (16).
(f) Remove nut (21) and light (22) from each light bracket (16).
4-181
|