TM 10-4320-324-14 (g)    Install eight lockwashers (25), then thread nuts (24) on to screws (26) and tighten. WARNING Potential health hazards result from inhalation of petroleum solvent vapors and from contact of solvent with skin. Use rubber gloves and hand cream for protection, and work with adequate ventilation. Petroleum  solvents  are  highly  flammable.    Keep  solvent  container  lids  closed  when  not  in  use,  and  avoid  all possible risks of igniting solvent vapors, keep away from open flame and excessive heat. Flash point of solvent is 100 to 138 degrees F (38 to 59 degrees C). (h)    Wipe mounting pad on connection (23) with a lint free cloth dampened in cleaning solvent.  Allow to air dry. (i)    Install plate (32) on connection (23). (j)    Install pressure line and elbow (17). (k)    Refer to steps 3 and 4 to install coupling halves and gate valves. (2) Installation of suction manifold. (a)    Install gasket (21) on pump assembly. (b)    Aline  match  marks,  then  position  suction manifold (18) against pump assembly. (c)    Install eight lockwashers (20), then thread eight   nuts   (19)   on   to   pump   assembly studs and tighten. (d)    Install suction hose (16) and elbow (17) at suction manifold (17). 4-175

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business