TM 10-4320-324-14
(g) Install eight lockwashers (25), then thread nuts (24) on to screws (26) and tighten.
WARNING
Potential health hazards result from inhalation of petroleum solvent vapors and from contact of solvent with skin.
Use rubber gloves and hand cream for protection, and work with adequate ventilation.
Petroleum solvents are highly flammable. Keep solvent container lids closed when not in use, and avoid all
possible risks of igniting solvent vapors, keep away from open flame and excessive heat. Flash point of solvent
is 100 to 138 degrees F (38 to 59 degrees C).
(h) Wipe mounting pad on connection (23) with a lint free cloth dampened in cleaning solvent. Allow to air
dry.
(i) Install plate (32) on connection (23).
(j) Install pressure line and elbow (17).
(k) Refer to steps 3 and 4 to install coupling halves and gate valves.
(2)
Installation of suction manifold.
(a) Install gasket (21) on pump assembly.
(b) Aline match marks, then position suction
manifold (18) against pump assembly.
(c) Install eight lockwashers (20), then thread
eight nuts (19) on to pump assembly
studs and tighten.
(d) Install suction hose (16) and elbow (17) at
suction manifold (17).
4-175
|