TM10-4320-324-14 4-46.  Starting Aid Pump Replacement. This task covers: a.    Removal b.    Installation INITIAL  SETUP: Tools Tool kit, general mechanics: automotive, item 32, section III, appendix B a.    Removal. WARNING Ether  is  extremely  flammable.    Do  not  remove tube    while    smoking    or    near    open    flames. Failure in doing so may result in damage to unit and injury to personnel. (1)    Remove ether tube (1). (2)    Turn knob (2) counterclockwise and remove. (3)    Remove nut (3) and pump (4). b.     Installation. (1)    Install  pump  (4)  with  tube  connection  at  twelve o'clock position. (2)    Install nut (3). (3)    Install knob (2) With pump shaft pulled out and nut on end of shaft held with wrench. (4)    Connect ether tube (1) to pump (4). END OF TASK 4-145