TM 10-4320-324-14
4-38. Main Wiring Harness Repair/Replacement (CONT).
(2) Remove two screws (4) and two wires (5)
from shutdown solenoid (6). Tag wires.
(3) Remove nut (7), flat washer (8), and wire (9)
from oil sending unit (10). Tag wire.
NOTE
If it is not possible to remove wires, remove
low oil pressure cut-out switch and oil
pressure sending unit as an assembly (para
4-56 and 4-57).
(4) Remove two screws (11) and three wires
(12) from oil pressure switch (13). Tag
wires.
4-114
|