TM 10-4320-324-14
4-30. Batteries and Cables Replacement (CONT).
b.
Cleaning/lnspection.
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only in a well
ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapor. Do not use near open flame
or excessive heat. The flash point is 100°F-1380F (38-50°C). If you become dizzy while using cleaning solvent,
get fresh air immediately and get medical aid. If contact with eyes is made, wash your eyes with water and get
medical aid immediately.
(1) Clean all wires, cables, battery posts, and terminals to remove corrosion buildup.
(2) Inspect cables and jumpers for any broken or frayed wires.
(3) Inspect terminals for any damaged nuts or bolts.
(4) Replace any defective components.
c.
Testing.
(1) Check lead wires and cables for continuity. If continuity is not indicated, replace.
(2) Check electrolyte level in batteries.
d.
Installation.
(1) Install negative cable (19), negative wire
(18), starwasher (17), lockwasher (16), and
bolt (15).
(2) Install negative wire (14), lockwasher (13),
and nut (12).
(3) Install two positive wires (11), positive cable
(10), lockwasher (9), and nut (8).
4-98
|