TM 10-4320-316-14
4-24. PUMP INLET/OUTLET PIPING AND SUCTION FLANGE ASSEMBLY REPAIR AND
REPLACEMENT. - Continued.
d. Repair. Repair is limited to replacement of parts found defective during inspection.
e. Installation.
(1) Install check valve weight (17), check valve weight (16), and screw (15) onto new gasket (18).
NOTE
Hinged area of gasket faces the top stud. Large weight should face the pump.
NOTE
Install suction flange with tapered, protruding edge facing bottom.
(2) Install gasket (14), suction flange (13), two lock washers (11), and two nuts (10) onto pump (12).
NOTE
Always wrap anti-seize tape around threads in the same direction as threads will rotate during installation.
(3) Wrap anti-seize tape around pipe threads and install nipple (8), coupling (7), gasket (6), and hose adapter (5) onto
pump (9) outlet.
(4) Wrap anti-seize tape around pipe threads and install nipple (3), coupling (2), and hose adapter (1) onto pump (4)
inlet.
4-48/(4-49 Blank)
|