Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: Cleaning
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM 10-4320-316-14 c.  Cleaning. (1)  Remove all build up of dirt, oil, and debris from all surfaces. WARNING Serious injury can result in breathing fumes of dry cleaning solvent P-D-680, Type III. Serious  injury  or  death  can  result  from  explosion  of  fumes  from  solvent.    When  using this solvent:  Clean parts in a well ventilated area.  Avoid inhalation of solvent fumes and prolonged exposure of skin to cleaning solvent.  Wash exposed skin thoroughly.  Do not use near open flame or excessive heat.  Flash point of solvent is 100°  F to 138°  F (38 C to 59° C).    Wear  eye  protection  when  blowing  solvent  from  parts.    Air  pressure  should  not  exceed  30  psig  (2.1 kg/cm2). (2)  Clean all metallic parts with a clean soft cloth or a medium bristle brush, and cleaning solvent.  Be sure that all gasket adhesive residue is removed if gasket material is being replaced. (3)  Allow parts to dry. d.  Repair.  Repair is limited to replacement of parts found defective during inspection. e.  Assembly.  (Refer to Figure 4-14.) (1)    If  foam  insulation  (6)  was  removed,  replace  foam  insulation.    Refer  to  Appendix  F  for  manufacturing instructions. (2)  Place sheet (5) into position on sheet (3) and install eleven rivets (4). (3)  Place sheet (2) into position on sheet (3) and install seven rivets (1). f.  Installation.  (Refer to Figure 4-13). (1)  Install sheet (4) and four screws (3). (2)  Place outlet enclosure assembly (3) into position on unit and install twelve screws (2). (3)  Install seven screws (1). (4)  Install access cover (see paragraph 4-18). (5)  Install roll-over frames (see paragraph 4-13). 4-45

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business