TM 10-4320-316-14
4-23. ENCLOSURE ASSEMBLY, OUTLET REPAIR AND REPLACEMENT.
This Task Covers:
a.
Removal
b.
Disassembly
c.
Cleaning
d.
Repair
e.
Assembly
f.
Installation
Initial Setup:
Tools Required
Tool Kit, General Mechanic's (Appendix B, Item 1)
Drill, Hand Portable (Appendix B, Item 2)
Riveter, Blind, Hand (Appendix B, Item 5)
Bit, Drill, .125 in. dia. (Appendix B, Item 2)
Shears, Bent, Trimmers (Appendix B, Item 2)
Material's Required
Cloth, Lint-Free (Appendix E, Item 1)
Brush, Medium Bristle (Appendix E, Item 2)
Solvent, Dry Cleaning (Appendix E, Item 3)
Equipment Condition
DED pump assembly shut down and cool.
NOTE
If outlet enclosure assembly is being removed for maintenance access only, do
not remove roll-over frames.
Roll-over handles removed (see paragraph 4-13).
Access cover removed (see paragraph 4-18).
Inlet enclosure assembly removed (see paragraph 4-22).
Compression release handle removed (see paragraph 4-14).
Throttle control assembly removed (see paragraph 4-15).
a. Removal. (Refer to Figure 4-13).
(1) Remove nineteen screws (1).
(2) Remove outlet enclosure assembly (2) from unit.
(3) Remove four screws (3) and sheet (4).
4-42
|