TM 10-4320-316-14
4-13. ROLL-OVER FRAME REPLACEMENT.
This Task Covers:
a.
Removal
b.
Installation
Initial Setup:
Tools Required
Tool Kit, General Mechanic's (Appendix B, Item 1)
Material's Required
None
Equipment Condition
DED pump assembly shut down and cool.
a. Removal (Refer to Figure 4-2).
(1)
Remove two screws.(1), two screws (2), and outlet side roll-over frame (3) from unit.
(2)
Remove two screws (4), two screws (5), and inlet side roll-over frame (6) from unit.
b.
Installation.
(1)
Install inlet side roll-over frame (6), two screws (5), and two screw (4).
(2)
Install outlet side roll-over frame (3), two screws (2), and two screw (1).
4-18
|