TM 10-4320-307-10
Table 2-2. Operator/Crew Preventive Maintenance Checks and Services - (Cont)
Item
Location
Not Fully
No.
Interval
Item to
Procedure
Mission Capable
Check/Service
if:
62
Weekly
Ether Start
WARNING
(At 32°F (0°C) or
Kit
Ether is highly flammable. Do not use near
lower) valve does
sparks or open flames. Do not inhale fumes. Do
not operate.
not actuate ether start kit more than once. Overloading
the engine air housing with this highly explosive fluid
(ether) could result in an explosion.
Check that ether cylinder (1) is firmly in place. The cylinder
should be finger tight in valve (2).
Inspect cylinder (1) and valve (2) for dents, corrosion, or other
damage.
Inspect the valve assembly (2) for corrosion or other damage.
Verify valve operation by pulling knob (3) for 3 seconds or less.
If the valve operates freely but no ether is released, replace
the cylinder (1) and test the valve again.
Inspect hose (4) for leaks or cracks. The hose should be se-
cured to fitting (5) at both ends.
2-53
|