TM 10-4320-307-10
Table 2-2. Preventive Maintenance Checks and Services
NOTE
If the equipment must be kept in continuous operation, check and service only those
items that can be checked and serviced without disturbing operation. Make the
complete checks and services when the equipment can be shut down.
Perform weekly as well as before operation PMCS if:
(1) You are the assigned operator and have not operated the item since the last weekly.
(2) You are operating the item for the first time.
Table 2-2. Operator/Crew Preventive Maintenance Checks and Services - (Cont)
Item
Location
Not Fully
No.
Interval
Item to
Procedure
Mission Capable
Check/Service
if:
1
Before
Exhaust
WARNING
Exhaust system
System
Severe burns can be caused by exhaust system
is leaking or
components heated during operation of the en-
components are
gine. It the engine has been running, do not
loose.
touch any components of the exhaust system
until they have cooled.
Check that spark arrestor and exhaust guard are securely
mounted.
Inspect muffler pipes (1) between muffler and turbocharger (2)
for loose connections, holes, or other damage.
Inspect flange (3) connection at turbocharger (2). The flange
must be secured with all mounting bolts and show no indica-
tions of cracks or leaks.
2-6
|