TM 10-4320-256-14&P
Table 3-1. operator Troubleshooting.
Malfunction
Test or Inspection
Corrective Action
1. ENGINE WILL NOT START OR IS HARD TO START
Step 1. Check position of ignition switch.
Place ignition switch in RUN position.
Step 2. Check choke position.
Choke should be in closed position for starting.
Step 3. Check for closed fuel control valve.
Open the fuel control valve.
Step 4. Check for empty fuel tank.
Refill the fuel tank (para. 2-13).
Step 5. Check for dirt in fuel system.
Service the fuel fitter (see TM 9-2805-257-14).
Step 6. Check for contaminated fuel.
Drain and refill fuel tank (para. 2-13).
2. ENGINE STARTS BUT WILL NOT CONTINUE TO RUN
Step 1. Check for insufficient fuel supply.
Refill the fuel tank (para. 2-13).
Step 2. Check for dirt in fuel system.
Service the fuel filter (see TM 9-2805-257-14)
Step 3. Check choke position.
If engine is cold, close choke.
If engine is warn, close choke half way.
3-3
|