TM 10-3835-231-13
5-8. WATER DETECTION KIT ADAPTER ASSEMBLY REPAIR. - continued
b.
Repair. Replace all defective parts to extent necessary for repair.
c.
Assembly.
(1)
Place antisieze tape on male threads of nipple assembly (6) and probe assembly (8).
(2)
Install probe assembly (8) into nipple assembly (6).
(3)
Install couplings (3) and (4) onto nipple assembly (6).
(4)
Install gaskets (7) into coupling (3) and cap (2).
(5)
Attach cap (2) and plug (1) with key rings (5).
(6)
Place plug (1) and cap (2) in position and close cam arms.
5-12
|