TM 10-3835-231-13 WARNING Equipment   must   be   grounded   and   bonded   at   time   of   installation   to   prevent explosion and fire. CAUTION Equipment damage can result if down stream pressure exceeds 125 psig. i. On  the  return  manifold,  connect  discharge  hose  (5)  between  outlet  side  of  meter  strainer  (6)  and  single  to double-groove adapter (9) using coupling clamps (1). j. Place 4 each drip pan (10), 2 each absorbent oil material (11) and 2 each storage drum (12) where they will be available for use if needed. k. Inspect all connections to verify correct installation of flanges, coupling gasket, clamps, and security of Cam- lock devices. 4-9. TANK FARM ASSEMBLY. NOTE The following assembly instructions apply to one tank farm assembly.  There are 3 tank farm assemblies for each fuel unit and 9 total for a TPT. a. Locate  and  install  2  each  5,000  BBL  collapsible  fabric  tanks  (1)  (figure  4-8).    Be  sure  that  elbows,  hoses, and valves supplied with tanks are installed. b. Position containers storing the remaining components near their respective installation sites near the fabric collapsible tanks (1). c. Remove remaining components from containers. d. Inspect all items for damage, cleanliness, and quantities required. WARNING GROUNDING AND BONDING Pumps  must  be  grounded  and  bonded  at  time  of  installation  to  prevent  explosion or fire. CAUTION Install pumps as far away from the tanks as possible.  The suction hose should lie on  the  ground  without  strain  on  the  tank  or  pump.    Pump  engines  and  exhaust fumes are hot and distance from the tank will enhance safety. e. Prepare  600  GPM  pump  (2)  for  use  in  accordance  with  TM  5-4320-305-10.    Observe  all  warnings  and cautions. 4-23

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business