TM  55-4920-383-13&P Table   4-4.   Troubleshooting   Chart   -   Continued Malfunction 6.   Resistance   measure- ments   incorrect. 7.   Underrange   blinking (resistance   measure- ments)  not  functioning. 8.  Unable  to  simulate specific   PROBE capacitance. Probable   cause Defective  RESISTANCE FUNCTION switch A2S4, RESISTANCE  RANGE switch  A2S5,  or  A2Z11, Z12,  Z14  and  associated circuitry. Defective   integrated   circuits A2Z1-10,   A2Z13   and associated   circuitry. a.   Defective   SIMULATORS- PROBE  0-7000  pF switch  A3S1,  0-800  pF switch  A3S2,  or capacitors  A3C1  through C7. b.  Defective  SIMULATORS- PROBE  A4C1. Corrective    action Check  and  replace  analog board  A2  as  required. Check  and  replace  analog board  A2  as  required. a.  Check  and  replace simulator  board  A3 as   required. b.  Check  and  replace  air capacitor  board  A4 as   required. 4-18

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business