TM  55-4920-383-13&P (2)  Set  DISPLAY  SELECT  switch  (8,  figure  2-1)  to  RES  (MEG)  and  RESISTANCE RANGE  switch  (12)  to  LOW  TEST  position.  Check  that  digital megohm. (3)  Set  RESISTANCE  RANGE  switch  (12)  to  HIGH  TEST display  (7)  reads  0.1000 position.   Check   that   digital display  (7)  reads  between  0.9400  and  0.9600  megohm. (4)  Set  test  fixture  switch  S1  (fig.  1-2)  to  position  1.  Perform  resistance  range checkout  by  setting  test  fixture  switches  S2  and  S3  and  RESISTANCE  RANGE  switch (12,  figure  2-1)  to  position  listed  for  tests  1  through  17  of  table  4-3.  Check  that  digital display  (7)  reads  between  minimum  and  maximum  values  listed  in  table  4-3  for  each  test. (5)  Set  RESISTANCE  RANGE  switch  (12)  to  1-10  position.  Set  test  fixture  switch  S2 to position 2 and S1 to position 1.    Check  that  digital  display  reads  0.000  with  underrange blinking. (6)  Set  test  fixture  switch  S2  to  position  6.    Check  that  digital  display  reads  9.900 megohms  with  overrange  blinking. (7)  Set  RESISTANCE  RANGE  switch  (12)  to  1K-10K  position  and  RESISTANCE  FUNC- TION  switch  (11)  to  A-C  position.  Set  test  fixture  switch  S2  to  position  10  and  S3  to  position  2. Check  that  digital  display  (7)  reads  between  4000  and  6000  megohms. (8)  Set  RESISTANCE  FUNCTION  switch  (11)  to  A-GND  position.  Set  test  fixture switch  S3  to  position  3.    Check  that  digital  display  reads  between  4000  and  6000  megohms. (9)  Set  RESISTANCE  FUNCTION  switch  (11)  to  B-GND  position.  Set  test  fixture switch  S3  to  position  4.    Check  that  digital  display  reads  between  4000  and  6000  megohms. (10)  Set  RESISTANCE  FUNCTION  switch  (11)  to  C-GND  position.  Set  test  fixture switch  S3  to  position  5. Check  that  digital  display  reads  between  4000  and  6000  megohms. (11)  Set  RESISTANCE  FUNCTION  switch  (11)  to  EXT  RES  position. switch S3 to position 6.    Check  that  digital  display  reads  between  4000  and Set  test  fixture 6000  megohms. 4-11

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business