TM 5-4320-306-24 2-18.  REPLACE/REPAIR SUCTION ASSEMBLY, STRAINER ASSEMBLY, AND GATE VALVE (Continued) 7 Loosen   hose   clamp   (1)   and   remove   suction pressure hose (2) from reducer (3) 8 Remove elbow (4) and reducer (3) from strainer body (5). 9 Unlock  locking  lever  (6)  and  remove  lever  bolt (7) 10 Remove  strainer  clamp  (8)  from  strainer  body (5). 11 Remove   strainer   (9)   and   preformed   packing (10).  Discard preformed packing. CLEANING/INSPECTION/REPAIR: 1 Inspect  flanges,  gate  valve,  strainer  body,  and  strainer  clamp  for  cracks,  rust,  corrosion,  and  for  damaged  or stripped threads.  Inspect mounting surfaces.  Make sure they are smooth and flat with no nicks or burrs. 2 Repair minor nicks or burrs and/or smooth out mounting surfaces with crocus abrasive cloth.  Clean interior or mounting  surfaces.    Clean  and  refinish  outside  surfaces  Remove  only  a  minimal  amount  of  surface  material, replace parts if necessary. 3 Inspect suction pressure hose (2).  Replace if brittle, cracked, or deteriorated.  Inspect hose clamp (1),  reducer (3), and 90-degree elbow (4) for damage, rust, or corrosion.  Replace parts if severely damaged or rusted. WARNING Dry    cleaning    solvent    P-D-680    (safety    or    Stoddard's    Solvent)    is    potentially dangerous.  Avoid repeated and prolonged breathing of vapors and skin contact with the liquid.  Do not use near open flame, arcing equipment, or other ignition source.  Always wear eye protection and protective clothing.  The flash point of P- D-680 is 100° to 138°F (38° to 59°C). Death or serious injury could occur if compressed air is directed against the skin. Do not use compressed air for cleaning or drying unless the pressure is/has been reduced to 30 psi (2.11 kgcm2) or less.  When working with compressed air always use chip guards, eye protection, and other personal protective equipment. 4 Clean strainer with dry cleaning solvent.  Dry with compressed air. 5 Inspect strainer for damage.  Replace if severely damaged. 2-69

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business