TM   5-4320-304-14 TM   08922A-14/1 4-13.   REPLACE   VOLUTE,   IMPELLER,   WEAR   PLATE,   SHAFT   SEAL,   AND ADAPTER   SHAFT This task covers: a.   Removal c.   Inspection b.   Cleaning d.    Installation INITIAL   SETUP Tools (A)   Tool   kit,   general   mechanics   automotive (USMC)  Tool  kit,  general  mechanics (A)   Shop   equipment,   automotive maintenance  and  repair Materials/Parts Dry  cleaning  solvent  (Item  10,  Appendix  E) Pump   repair   kit Equipment Condition Para Equipment Condition 4-12 Suction  inlet  flange  and  check valve removed from pump case assembly. General  Safety  Instructions Well-ventilated  area  required  during  cleaning. REMOVAL: 1 Remove  nuts  (1)  and  washers  (2)  securing  volute  (3)  to  pump  case  assembly  (4). 2 Remove  packing  (5)  and  discard. 3 Prevent  adapter  shaft  (6)  from  moving  and  remove  screw  (7)  and  lock  washer  (8). 4-15

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business