16. Stopping the Equipment
a. Refer to figure 8 to stop the pumping
assembly.
Caution: Except in case of emergency, al-
ways idle pump three minutes to allow engine
parts to cool to prevent vapor lock at shut-
down.
b. Perform the necessary daily preventive
maintenance services (para 30).
17. Operation Under Usual Conditions
a. Start the pumping assembly (para 15).
Figure 7 (2)--Continued.
Figure 8 (l). Stopping the pumping assembly.
Figure 7 (3)--Continued.
b. Refer to figure 7 to start the pumping
assembly.
Note. Priming the pump is necessary only after
initial starting at a new location or when pump has
Figure 8 (2)--Continued.
lost prime from a long period of disuse. Pump is
normally self-priming.