TM 10-4320-343-14 4.13.11 Run Relay K2 Replacement. (Regulated Model ADC1500 only) This   task   covers: 4.13.11.1   Removal 4 . 1 3 .1 1 . 2    I n s t a l l a t i on INITIAL SETUP Tools General   Mechanic’s   Tool Section   III,   Item   1) Material/Parts Equipment    Conditions Equipment   shut   down,   refer   to Kit   (appendix   B, paragraph   2.5.1.2   or   2.5.2.2. Lockwashers   (TM   10-4320-343-24P) Lock   nuts   (TM   10-4320-343-24P) Gasket   (TM   10-4320-343-24P) Tags   (appendix   E,   Section   II,   Item General    Safety   Instructions To   prevent   rolling   or   sliding,   do   not work   on   equipment   that   is   not   securely s t a b i l i z e d. 12) DO  not  work  on  equipment  without following   standard   shop   safety precautions. Figure   4-51. Run Relay K2 Replacement (Regulated   Model   ADC1500   only). 4-95